上海秉越多功能血液溶漿機注意事項:
1、平時(shi)設定水(shui)溫,可長(chang)期開(kai)(kai)機(ji),用時(shi)將(jiang)擺幅開(kai)(kai)關打開(kai)(kai),設定頻率,自動(dong)搖(yao)擺,用完關掉搖(yao)擺開(kai)(kai)關,節約用電,減少機(ji)械磨損。
2、使(shi)用前定要(yao)將水(shui)(shui)加(jia)到水(shui)(shui)位線,切勿干燒,以保護加(jia)熱管。隨著開機時間的不斷增(zeng)長,水(shui)(shui)箱(xiang)的水(shui)(shui)會逐漸蒸發,請隨時檢查水(shui)(shui)位(加(jia)水(shui)(shui)換水(shui)(shui))。確(que)保機器正常運轉。
3、設(she)定(ding)溫(wen)度:按(an)SET鍵(jian)(jian)(jian)可設(she)定(ding)或查看溫(wen)度設(she)定(ding)點。按(an)下SET鍵(jian)(jian)(jian)管字符開始閃動(dong),表示儀表進入設(she)定(ding)狀態(tai),按(an)△鍵(jian)(jian)(jian)設(she)定(ding)值增加,按(an)△或▽鍵(jian)(jian)(jian)數據會(hui)快速變動(dong),再(zai)次按(an)SET鍵(jian)(jian)(jian)儀表回到正(zheng)常工作(zuo)狀態(tai)溫(wen)度設(she)定(ding)完畢,開始加熱指(zhi)示燈亮。
4、提(ti)(ti)前(qian)(qian)設置:按SET鍵(jian)3秒儀表(biao)進入內(nei)層參(can)(can)數(shu)(shu)設定狀(zhuang)態(tai)。*個出(chu)(chu)現并閃動(dong)的參(can)(can)數(shu)(shu)為(wei)即停(ting)止的提(ti)(ti)前(qian)(qian)量(liang)(liang),提(ti)(ti)前(qian)(qian)量(liang)(liang)參(can)(can)數(shu)(shu)要(yao)慎重調整(zheng),為(wei)減少(shao)溫(wen)度過(guo)沖,儀表(biao)控制(zhi)(zhi)加(jia)熱(re)輸出(chu)(chu)時(shi)(shi)會(hui)提(ti)(ti)前(qian)(qian)截止加(jia)熱(re),當(dang)溫(wen)度下(xia)跌(die)(die)到提(ti)(ti)前(qian)(qian)量(liang)(liang)以(yi)下(xia)時(shi)(shi)又(you)開始加(jia)熱(re),在設定值(zhi)與提(ti)(ti)前(qian)(qian)量(liang)(liang)范圍(wei)內(nei)輸出(chu)(chu)(繼(ji)電(dian)器(qi))是不會(hui)工(gong)作的,這(zhe)樣可減少(shao)繼(ji)電(dian)器(qi)動(dong)作次(ci)數(shu)(shu)以(yi)延長繼(ji)電(dian)器(qi)使用壽命。例:若(ruo)設定值(zhi)為(wei)50.0℃,提(ti)(ti)前(qian)(qian)量(liang)(liang)為(wei)0.5,儀表(biao)控制(zhi)(zhi)加(jia)熱(re)到49.5.0時(shi)(shi)繼(ji)電(dian)器(qi)釋放,溫(wen)度下(xia)跌(die)(die)到50.0℃-0.5℃=49.5℃時(shi)(shi)繼(ji)電(dian)器(qi)又(you)吸合。提(ti)(ti)前(qian)(qian)量(liang)(liang)越(yue)大(da)繼(ji)電(dian)器(qi)動(dong)作次(ci)數(shu)(shu)越(yue)少(shao),提(ti)(ti)前(qian)(qian)量(liang)(liang)過(guo)大(da)會(hui)降低控制(zhi)(zhi)精度。調整(zheng)好提(ti)(ti)前(qian)(qian)量(liang)(liang)參(can)(can)數(shu)(shu)后(hou)按SET鍵(jian)3秒儀表(biao)回到工(gong)作狀(zhuang)態(tai)。﹙注意:提(ti)(ti)前(qian)(qian)設置是為(wei)防止加(jia)熱(re)停(ting)止后(hou)溫(wen)沖過(guo)高而(er)專門設置的,般(ban)情況下(xia)不需要(yao)修改﹚。
5.誤差的(de)修(xiu)(xiu)正(zheng)(zheng)(zheng):在(zai)確(que)認儀(yi)表(biao)顯(xian)示的(de)值(zhi)不是正(zheng)(zheng)(zheng)確(que)的(de)測量值(zhi)時可對顯(xian)示值(zhi)進行修(xiu)(xiu)正(zheng)(zheng)(zheng)。按(an)SET鍵3秒進入儀(yi)表(biao)深層菜單,*個出(chu)現(xian)并(bing)閃動(dong)的(de)參(can)(can)數(shu)(shu)為E00即(ji)提(ti)前量,再按(an)次SET鍵出(chu)現(xian)閃動(dong)的(de)參(can)(can)數(shu)(shu)即(ji)誤差修(xiu)(xiu)正(zheng)(zheng)(zheng)參(can)(can)數(shu)(shu),配合(he)△或(huo)▽鍵可修(xiu)(xiu)改此(ci)參(can)(can)數(shu)(shu)。誤差的(de)修(xiu)(xiu)正(zheng)(zheng)(zheng)范圍確(que)的(de)儀(yi)表(biao)修(xiu)(xiu)正(zheng)(zheng)(zheng)不正(zheng)(zheng)(zheng)確(que)。為-9.9℃到+9.9℃,休正(zheng)(zheng)(zheng)完后再按(an)下SET鍵退出(chu)。儀(yi)表(biao)出(chu)廠時修(xiu)(xiu)正(zheng)(zheng)(zheng)值(zhi)為0.0。
以(yi)質量求生存,以(yi)信譽求發展,滿(man)足合(he)同規(gui)定及潛在需求!
全國咨詢熱線
021-61996076 021-58920620